Warning Icon

For other alternatives, please contact us for more information.

0 Alternative products available

P-MP

Base Product
  • Available in:
  • Asia
  • Australia/New Zealand
  • Latin America
  • Middle East/Africa
  • North America

Fiber Optic Cable, Indoor Plenum, Loose Tube Cordage

Configure Product Variants
Find a Partner
Specifications
Finish making your selections or clear them to view relevant specifications.

Your web browser (Internet Explorer 11 or lower) is out of date and the functions below will not work with Internet Explorer.
Update your browser for more security, speed, functionality and experience on this site.

Update browser

Product Variants Show All Clear

Configure and display product variants of P-MP by selecting options

Loading...
Product
Jacket Marking Regional Availability Portfolio Product Type Product Series Cable Type Construction Type Jacket Color Total Fiber Count Fiber Type Environmental Space
760251014 | P-016-MP-8G1-F16YL 760251014 | P-016-MP-8G1-F16YL
Fiber indoor cable, Plenum MPO Trunk, 16 fiber, Singlemode G.657.A2/B2, Feet jacket marking, Yellow jacket color
Feet Asia | Australia/New Zealand | Latin America | Middle East/Africa | North America CommScope® Fiber indoor cable P-MP MPO trunk cable Non-armored Yellow 16 G.657.A2/B2 | G.657.A2/B2 Plenum
760251015 | P-032-MP-8G1-F16YL 760251015 | P-032-MP-8G1-F16YL
Fiber indoor cable, Plenum MPO Trunk, 32 fiber with 16 fiber subunits,, Singlemode G.657.A2/B2 Feet jacket marking, Yellow jacket color
Feet Asia | Australia/New Zealand | Latin America | Middle East/Africa | North America CommScope® Fiber indoor cable P-MP MPO trunk cable Non-armored Yellow 32 G.657.A2/B2 | G.657.A2/B2 Plenum
760251016 | P-048-MP-8G1-F16YL 760251016 | P-048-MP-8G1-F16YL
Plenum MPO Trunk Cable, 48 fiber multi-unit with 16 fiber subunits
Feet Asia | Australia/New Zealand | Latin America | Middle East/Africa | North America CommScope® Fiber indoor cable P-MP MPO trunk cable Non-armored Yellow 48 G.657.A2/B2 | G.657.A2/B2 Plenum
760251017 | P-064-MP-8G1-F16YL 760251017 | P-064-MP-8G1-F16YL
Fiber indoor cable, Plenum MPO Trunk, 64 fiber multi-unit with 16 fiber subunits, Singlemode G.657.A2/B2, Feet jacket marking, Yellow jacket color
Feet Asia | Australia/New Zealand | Latin America | Middle East/Africa | North America CommScope® Fiber indoor cable P-MP MPO trunk cable Non-armored Yellow 64 G.657.A2/B2 | G.657.A2/B2 Plenum
760251018 | P-096-MP-8G1-F16YL 760251018 | P-096-MP-8G1-F16YL
Fiber indoor cable, Plenum MPO Trunk, 96 fiber multi-unit with 16 fiber subunits, Singlemode G.657.A2/B2, Feet jacket marking, Yellow jacket color
Feet Asia | Australia/New Zealand | Latin America | Middle East/Africa | North America CommScope® Fiber indoor cable P-MP MPO trunk cable Non-armored Yellow 96 G.657.A2/B2 | G.657.A2/B2 Plenum
760251019 | P-128-MP-8G1-F16YL 760251019 | P-128-MP-8G1-F16YL
Fiber indoor cable, Plenum MPO Trunk, 128 fiber multi-unit with 16 fiber subunits, Singlemode G.657.A2/B2, Feet jacket marking, Yellow jacket color
Feet Asia | Australia/New Zealand | Latin America | Middle East/Africa | North America CommScope® Fiber indoor cable P-MP MPO trunk cable Non-armored Yellow 128 G.657.A2/B2 | G.657.A2/B2 Plenum
760251020 | P-144-MP-8G1-F16YL 760251020 | P-144-MP-8G1-F16YL
Plenum MPO Trunk Cable, 144 fiber multi-unit with 16 fiber subunits
Feet Asia | Australia/New Zealand | Latin America | Middle East/Africa | North America CommScope® Fiber indoor cable P-MP MPO trunk cable Non-armored Yellow 144 G.657.A2/B2 | G.657.A2/B2 Plenum
760251021 | P-192-MP-8G1-F16YL 760251021 | P-192-MP-8G1-F16YL
Plenum MPO Trunk Cable, 192 fiber multi-unit with 16 fiber subunits
Feet Asia | Australia/New Zealand | Latin America | Middle East/Africa | North America CommScope® Fiber indoor cable P-MP MPO trunk cable Non-armored Yellow 192 G.657.A2/B2 | G.657.A2/B2 Plenum

Product Classification

Regional Availability Asia | Australia/New Zealand | Latin America | Middle East/Africa | North America
Portfolio CommScope®
Product Type Fiber indoor cable
Product Series P-MP

General Specifications

Cable Type MPO trunk cable
Construction Type Non-armored
Subunit Type Gel-free

Ordering Tree

Click on image to enlarge.

Mechanical Specifications

Compression 10 N/mm | 57.101 lb/in
Compression Test Method FOTP-41 | IEC 60794-1 E3
Flex 300 cycles
Flex Test Method FOTP-104 | IEC 60794-1 E6
Impact Test Method FOTP-25 | IEC 60794-1 E4
Strain See long and short term tensile loads
Strain Test Method FOTP-33 | IEC 60794-1 E1
Twist 10 cycles
Twist Test Method FOTP-85 | IEC 60794-1 E7

Environmental Specifications

Installation temperature 0 °C to +70 °C (-32 °F to +158 °F)
Operating Temperature 0 °C to +70 °C (+32 °F to +158 °F)
Storage Temperature -40 °C to +70 °C (-40 °F to +158 °F)
Cable Qualification Standards ANSI/ICEA S-83-596 | Telcordia GR-409
Environmental Space Plenum
Flame Test Listing NEC OFNP (UL) and c(UL)
Flame Test Method NFPA 130 | NFPA 262

Environmental Test Specifications

Heat Age 0 °C to +85 °C (+32 °F to +185 °F)
Heat Age Test Method IEC 60794-1 F9
Low High Bend 0 °C to +70 °C (+32 °F to +158 °F)
Low High Bend Test Method FOTP-37 | IEC 60794-1 E11
Temperature Cycle 0 °C to +70 °C (+32 °F to +158 °F)
Temperature Cycle Test Method FOTP-3 | IEC 60794-1 F1

Product Classification

Regional Availability Asia | Australia/New Zealand | Latin America | Middle East/Africa | North America
Portfolio CommScope®
Product Type Fiber indoor cable
Product Series P-MP

General Specifications

Cable Type MPO trunk cable
Construction Type Non-armored
Subunit Type Gel-free

Mechanical Specifications

Compression 10 N/mm | 57.101 lb/in
Compression Test Method FOTP-41 | IEC 60794-1 E3
Flex 300 cycles
Flex Test Method FOTP-104 | IEC 60794-1 E6
Impact Test Method FOTP-25 | IEC 60794-1 E4
Strain See long and short term tensile loads
Strain Test Method FOTP-33 | IEC 60794-1 E1
Twist 10 cycles
Twist Test Method FOTP-85 | IEC 60794-1 E7

Environmental Specifications

Installation temperature 0 °C to +70 °C (-32 °F to +158 °F)
Operating Temperature 0 °C to +70 °C (+32 °F to +158 °F)
Storage Temperature -40 °C to +70 °C (-40 °F to +158 °F)
Cable Qualification Standards ANSI/ICEA S-83-596 | Telcordia GR-409
Environmental Space Plenum
Flame Test Listing NEC OFNP (UL) and c(UL)
Flame Test Method NFPA 130 | NFPA 262

Environmental Test Specifications

Heat Age 0 °C to +85 °C (+32 °F to +185 °F)
Heat Age Test Method IEC 60794-1 F9
Low High Bend 0 °C to +70 °C (+32 °F to +158 °F)
Low High Bend Test Method FOTP-37 | IEC 60794-1 E11
Temperature Cycle 0 °C to +70 °C (+32 °F to +158 °F)
Temperature Cycle Test Method FOTP-3 | IEC 60794-1 F1